Files
klp-oa/klp-wms/src/main/java/com/klp/service/impl/WmsInspectionDetailServiceImpl.java
Joshi 0d40774194 feat(wms): 添加检验管理模块功能
- 新增检验项目明细相关实体类、业务对象、视图对象及服务接口
- 实现检验项目明细的增删改查、分页查询及数据校验功能
- 新增检验主记录相关实体类、业务对象、视图对象及服务接口
- 实现检验主记录的增删改查、分页查询及数据校验功能
- 新增金属材料室温拉伸试验相关实体类、业务对象、视图对象及服务接口
- 实现拉伸试验记录的增删改查、分页查询及数据校验功能
- 配置MyBatis映射文件及Excel导出功能
- 添加相应的控制器及参数验证规则
2026-06-13 13:02:43 +08:00

116 lines
4.0 KiB
Java

package com.klp.service.impl;
import cn.hutool.core.bean.BeanUtil;
import com.klp.common.core.page.TableDataInfo;
import com.klp.common.core.domain.PageQuery;
import com.baomidou.mybatisplus.extension.plugins.pagination.Page;
import com.baomidou.mybatisplus.core.conditions.query.LambdaQueryWrapper;
import com.baomidou.mybatisplus.core.toolkit.Wrappers;
import lombok.RequiredArgsConstructor;
import org.springframework.stereotype.Service;
import com.klp.domain.bo.WmsInspectionDetailBo;
import com.klp.domain.vo.WmsInspectionDetailVo;
import com.klp.domain.WmsInspectionDetail;
import com.klp.mapper.WmsInspectionDetailMapper;
import com.klp.service.IWmsInspectionDetailService;
import com.klp.common.utils.StringUtils;
import java.util.List;
import java.util.Map;
import java.util.Collection;
/**
* 检验项目明细Service业务层处理
*
* @author klp
* @date 2026-06-13
*/
@RequiredArgsConstructor
@Service
public class WmsInspectionDetailServiceImpl implements IWmsInspectionDetailService {
private final WmsInspectionDetailMapper baseMapper;
/**
* 查询检验项目明细
*/
@Override
public WmsInspectionDetailVo queryById(Long detailId){
return baseMapper.selectVoById(detailId);
}
/**
* 查询检验项目明细列表
*/
@Override
public TableDataInfo<WmsInspectionDetailVo> queryPageList(WmsInspectionDetailBo bo, PageQuery pageQuery) {
LambdaQueryWrapper<WmsInspectionDetail> lqw = buildQueryWrapper(bo);
Page<WmsInspectionDetailVo> result = baseMapper.selectVoPage(pageQuery.build(), lqw);
return TableDataInfo.build(result);
}
/**
* 查询检验项目明细列表
*/
@Override
public List<WmsInspectionDetailVo> queryList(WmsInspectionDetailBo bo) {
LambdaQueryWrapper<WmsInspectionDetail> lqw = buildQueryWrapper(bo);
return baseMapper.selectVoList(lqw);
}
private LambdaQueryWrapper<WmsInspectionDetail> buildQueryWrapper(WmsInspectionDetailBo bo) {
Map<String, Object> params = bo.getParams();
LambdaQueryWrapper<WmsInspectionDetail> lqw = Wrappers.lambdaQuery();
lqw.eq(bo.getMainId() != null, WmsInspectionDetail::getMainId, bo.getMainId());
lqw.like(StringUtils.isNotBlank(bo.getItemName()), WmsInspectionDetail::getItemName, bo.getItemName());
lqw.eq(bo.getItemValue() != null, WmsInspectionDetail::getItemValue, bo.getItemValue());
lqw.eq(StringUtils.isNotBlank(bo.getItemUnit()), WmsInspectionDetail::getItemUnit, bo.getItemUnit());
lqw.eq(bo.getUpperLimit() != null, WmsInspectionDetail::getUpperLimit, bo.getUpperLimit());
lqw.eq(bo.getLowerLimit() != null, WmsInspectionDetail::getLowerLimit, bo.getLowerLimit());
lqw.eq(StringUtils.isNotBlank(bo.getRangeDesc()), WmsInspectionDetail::getRangeDesc, bo.getRangeDesc());
return lqw;
}
/**
* 新增检验项目明细
*/
@Override
public Boolean insertByBo(WmsInspectionDetailBo bo) {
WmsInspectionDetail add = BeanUtil.toBean(bo, WmsInspectionDetail.class);
validEntityBeforeSave(add);
boolean flag = baseMapper.insert(add) > 0;
if (flag) {
bo.setDetailId(add.getDetailId());
}
return flag;
}
/**
* 修改检验项目明细
*/
@Override
public Boolean updateByBo(WmsInspectionDetailBo bo) {
WmsInspectionDetail update = BeanUtil.toBean(bo, WmsInspectionDetail.class);
validEntityBeforeSave(update);
return baseMapper.updateById(update) > 0;
}
/**
* 保存前的数据校验
*/
private void validEntityBeforeSave(WmsInspectionDetail entity){
//TODO 做一些数据校验,如唯一约束
}
/**
* 批量删除检验项目明细
*/
@Override
public Boolean deleteWithValidByIds(Collection<Long> ids, Boolean isValid) {
if(isValid){
//TODO 做一些业务上的校验,判断是否需要校验
}
return baseMapper.deleteBatchIds(ids) > 0;
}
}